Southwire 250 ft. 10/2 Gray Solid CU UF-B W/G Wire 13056755
Southwire 250 ft. 10/2 Gray Solid CU UF-B W/G Wire 13056755
Description
250-Feet 10 / 2 Solid UF-B Wire W/G ( By-the-roll )
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground
Southwire UF-B cable is used in applications that include outside lamp posts, pumps and other loads. It can also be used for outbuildings such as garages and barns. UF-B feeds from a distribution point in an existing building. UF-B has a heat capacity of 90 degree Celsius and is rated at 600 volt. UL Listed and CSA Certified.
PVC insulation and a nylon, color coded jacket
Southwire 13056755 Southwire 250 Ft. 10 AWG 2-Conductor UFW/G Electrical Wire 13056755
View local codes for direct burial at www.nfpa.org/freeaccess
UL listed and CSA certified
10 AWG undgerground wire for lamp posts, pumps and other loads
Direct Burial Uf-B Underground Fedder Cable, 10/2, 250 Ft. Per Roll
Available with 2 or 3 conductors with or without a ground wire
Used indoors for wet or corrosive locations
Type UF-B cable is designed specifically for use as underground feeder cable for direct earth burial in branch circuits, and indoors for wet or corrosive locations. Highly resistant to acids, alkalis, corrosive fumes, chemicals, lubricants, and ground water. It is noncorroding, sunlight-resistant, and will not support combustion. UL (Underwriter's Laboratories) listed.Length: 250 Ft.\nSize: 10 AWG\nNumber Of Conductors: 2 Conductors\nConductor Material: Copper\nType: UF-B\nVoltage: 600V\nTemperature Rating: 75 deg C\nCertification: UL Listed\n 0 -
WIRE 10/2-UFWG 250'
Note: product may vary by store
Resistant to sunlight, moisture and fungus
UF outdoor direct burial wire is resistant to moisture and light
Southwire's copper UF-B cable is used in applications that include outside lamp posts, pumps and other loads. It can also be used for outbuildings such as garages and barns. UF-B feeds from a distribution point in an existing building. UF-B has a heat capacity of 90 degree C and is rated at 600-Volt. UL Listed and CSA Certified.
Southwire's copper UF-B cable is used in applications that include outside lamp posts, pumps and other loads. It can also be used for outbuildings such as garages and barns. UF-B feeds from a distribution point in an existing building. UF-B has a heat capacity of 90°C and is rated at 600-Volt. UL Listed and CSA Certified.
UF-B Underground Feeder Cable, 10/2 AWG, 250 ft Applications Southwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2008 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts. Specifications Southwire Type UF-B cable meets or exceeds UL Standard 83, UL Standard 493, Federal Specification A-A-59544, and requirements of the National Electrical Code. Construction Southwire Type UF-B cable is manufactured as a 2 conductor cable without a ground wire. Copper conductors are annealed (soft) copper, solid or compressed stranded. Phase conductors are polyvinyl chloride (PVC) insulated, nylon jacketed, color coded for identification purposes. Jacketed with sunlight, moisture and fungus resistant gray PVC.
UF-B Underground Feeder Cable, 10/2 AWG, 250 ft Applications Southwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2008 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts. Specifications Southwire Type UF-B cable meets or exceeds UL Standard 83, UL Standard 493, Federal Specification A-A-59544, and requirements of the National Electrical Code. Construction Southwire Type UF-B cable is manufactured as a 2 conductor cable without a ground wire. Copper conductors are annealed (soft) copper, solid or compressed stranded. Phase conductors are polyvinyl chloride (PVC) insulated, nylon jacketed, color coded for identification purposes. Jacketed with sunlight, moisture and fungus resistant gray PVC.
Conductors are made of annealed (soft) copper
250' 10-2 Ufw/G Wire
Southwire's copper UF-B cable is used in applications that include outside lamp posts, pumps and other loads. It can also be used for outbuildings such as garages and barns. UF-B feeds from a distribution point in an existing building. UF-B has a heat capacity of 90C and is rated at 600-Volt. UL Listed and CSA Certified.
Used outdoors for direct burial
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Uf-B Cable Is Used In Applications That Include Outside Lamp Posts, Pumps And Other Loads. It Can Also Be Used For Outbuildings Such As Garages And Barns. Uf-B Feeds From A Distribution Point In An Existing Building. Uf-B Has A Heat Capacity Of 90
Southwire Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2008 National Electrical Code. UF-B cable may be used underground, including direct burial Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90C (with ampacity limited to that for 60C conductors) as specified by the National Electrical Code UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code Voltage rating for UF-B cable is 600 volts.
Item Details
Pickup Location
7440 Dean Martin Dr Suite 204
Las Vegas, NV, 89139
Quality
brand
SouthwireEstimated Retail Price
$318.00
color
Graysize
3.5 in x 13.5 in x 3.5 inBuyers Premium
15%
Inventory Number
1038720792
Found in


See the deals
Get in on the action, thousands of new items added daily. Bid and win!
Start bidding now